COMPONENT TECHNICAL DOSSIER
ThermoSnow Indicator
The snowflake does not display a numerical temperature; it makes the wall’s transition through a designed cold range visible.

01 · PRINCIPLE & RATIONALE
Intended function
and associated requirement.
The snowflake does not display a numerical temperature; it makes the wall’s transition through a designed cold range visible.
At a glance, the user can recognise when the bottle is within the intended cool range—without a battery, app or display.
Makes the intended cold range visible through a passive, reversible thermochromic snowflake. Reversible thermochromic microcapsules operate in a local layer protected by PHBH film. A thin thermal bridge reduces lag between water, wall and indicator. 8 ± 2 °C and ≤15 s are targets to be calibrated on the real wall; the symbol does not certify potability or the exact temperature of the full volume.
02 · TECHNOLOGY STACK
Technologies, roles
and approval gates.
Reversible thermochromic microcapsules
- Role
- Change contrast across the designed temperature band.
- Why
- Communicate cold without a battery, display or app.
- Approval gate
- ΔE/T curve, hysteresis and 200 cycles.
Local thermal bridge
- Role
- Reduces lag between water, wall and patch.
- Why
- Prevents the symbol reacting too late.
- Approval gate
- Transient model plus thermocouples.
PHBH cover film
- Role
- Contains and protects the active layer.
- Why
- Keeps microcapsules isolated in use and transport.
- Approval gate
- Peel, haze, migration and NIAS.
03 · ARCHITECTURE
Function, material
and interfaces.
Reversible thermochromic microcapsules operate in a local layer protected by PHBH film. A thin thermal bridge reduces lag between water, wall and indicator.
- Protected external recess
- body thermal bridge
- 01Protected external patch
- 02Target 0.35 mm local thermal bridge
- 0320–40 µm active layer
- 04Non-electronic colour reading
04 · MASTER PARAMETER REGISTER
Everything to be defined,
measured or certified.
A field without evidence is never filled with an invented number: it remains “To be determined”, together with the method required to close it. This is what makes the technical record verifiable.
01Identification & function3 PARAMETERS
| ID | Parameter | Symbol | Value | Unit | Tolerance | Condition | Method | Status |
|---|---|---|---|---|---|---|---|---|
| P03-001 | Assembly code | ID | P03 | — | To be defined | 23 °C / 50% RH unless noted | CAD, CAE or dedicated test | DESIGN BASIS |
| P03-002 | Designation | NAME | ThermoSnow | — | To be defined | 23 °C / 50% RH unless noted | CAD, CAE or dedicated test | DESIGN BASIS |
| P03-X001 | Intended use | USE | To be determined | — | To be defined | Full use cycle | Design review + user study | TO BE VALIDATED |
02Risk & maturity2 PARAMETERS
| ID | Parameter | Symbol | Value | Unit | Tolerance | Condition | Method | Status |
|---|---|---|---|---|---|---|---|---|
| P03-003 | Architecture revision | REV | R2 | — | To be defined | 23 °C / 50% RH unless noted | CAD, CAE or dedicated test | DESIGN BASIS |
| P03-004 | Technology readiness | TRL | 2–3 | level | To be defined | 23 °C / 50% RH unless noted | CAD, CAE or dedicated test | TO BE VALIDATED |
03Food contact3 PARAMETERS
| ID | Parameter | Symbol | Value | Unit | Tolerance | Condition | Method | Status |
|---|---|---|---|---|---|---|---|---|
| P03-005 | Declaration of Compliance | DoC | required | document | To be defined | 23 °C / 50% RH unless noted | CAD, CAE or dedicated test | CERTIFICATION REQUIRED |
| P03-014 | Intelligent-system migration | MIG | compliant | — | EC 450/2009 | 23 °C / 50% RH unless noted | CAD, CAE or dedicated test | CERTIFICATION REQUIRED |
| P03-X007 | Overall and specific migration | MIG | To be determined | mg/kg | Applicable limits | Simulant/time/temperature | Accredited methods | TO BE VALIDATED |
04Quality control3 PARAMETERS
| ID | Parameter | Symbol | Value | Unit | Tolerance | Condition | Method | Status |
|---|---|---|---|---|---|---|---|---|
| P03-006 | Lot traceability | LOT | 100 | % | To be defined | 23 °C / 50% RH unless noted | CAD, CAE or dedicated test | TARGET |
| P03-015 | End-of-line colour state | VISION | 100 | % | To be defined | 23 °C / 50% RH unless noted | CAD, CAE or dedicated test | TARGET |
| P03-X006 | Process capability | Cpk | To be determined | — | Target to be defined | Critical CTQ | SPC ≥30 samples | TO BE VALIDATED |
05Geometry & metrology5 PARAMETERS
| ID | Parameter | Symbol | Value | Unit | Tolerance | Condition | Method | Status |
|---|---|---|---|---|---|---|---|---|
| P03-007 | Active symbol diameter | Dact | 10 | mm | To be defined | 23 °C / 50% RH unless noted | CAD, CAE or dedicated test | DESIGN BASIS |
| P03-008 | Recess diameter | Drec | 14 | mm | To be defined | 23 °C / 50% RH unless noted | CAD, CAE or dedicated test | TARGET |
| P03-009 | Local thermal bridge | tbridge | 0.35 | mm | To be defined | 23 °C / 50% RH unless noted | CAD, CAE or dedicated test | TARGET |
| P03-010 | Microcapsule layer | tTC | 20–40 | µm | To be defined | 23 °C / 50% RH unless noted | CAD, CAE or dedicated test | TARGET |
| P03-X002 | Nominal mass | m | To be determined | g | To be defined | 23 °C / 50% RH | Balance 0.001 g | TO BE VALIDATED |
06Thermal properties3 PARAMETERS
| ID | Parameter | Symbol | Value | Unit | Tolerance | Condition | Method | Status |
|---|---|---|---|---|---|---|---|---|
| P03-011 | Transition threshold | Tswitch | 8 ± 2 | °C | To be defined | 23 °C / 50% RH unless noted | CAD, CAE or dedicated test | TARGET |
| P03-012 | Response time | tresp | ≤15 | s | After wall stabilisation | 23 °C / 50% RH unless noted | CAD, CAE or dedicated test | TARGET |
| P03-X004 | Service-temperature range | Tservice | To be determined | °C | To be defined | Use and transport | Climate chamber | TO BE VALIDATED |
07Durability & reliability1 PARAMETERS
| ID | Parameter | Symbol | Value | Unit | Tolerance | Condition | Method | Status |
|---|---|---|---|---|---|---|---|---|
| P03-013 | Colour endurance | Ncycle | 200 | cycles | To be defined | 23 °C / 50% RH unless noted | CAD, CAE or dedicated test | TARGET |
08Material1 PARAMETERS
| ID | Parameter | Symbol | Value | Unit | Tolerance | Condition | Method | Status |
|---|---|---|---|---|---|---|---|---|
| P03-X003 | Commercial grade and supplier | GRADE | To be determined | — | Qualified grade | Production lot | CoA + traceability | TO BE VALIDATED |
09Mechanical properties1 PARAMETERS
| ID | Parameter | Symbol | Value | Unit | Tolerance | Condition | Method | Status |
|---|---|---|---|---|---|---|---|---|
| P03-X005 | Drop resistance | Hdrop | To be determined | m | To be defined | Defined orientations | Instrumented drop test | TO BE VALIDATED |
10Recyclability1 PARAMETERS
| ID | Parameter | Symbol | Value | Unit | Tolerance | Condition | Method | Status |
|---|---|---|---|---|---|---|---|---|
| P03-X008 | Territory-specific end-of-life route | EOL | To be determined | — | Country/area defined | Complete assembly | Infrastructure mapping | TO BE VALIDATED |
05 · INDUSTRIALISATION
From material
to final inspection.
Qualified material
Thermochromic microcapsules + PHBH cover film
Process within window
Printing/deposition + encapsulation + sealing
Controlled interfaces
Protected external recess · body thermal bridge
CTQ + traceability
Deposition or printing, encapsulation and sealing must ensure position, thickness and 100% end-of-line colour inspection.
06 · DVP&R
A function is approved
only after passing its test.
| Test | Requirement | Risk | Method | Condition | Samples | Acceptance | Output |
|---|---|---|---|---|---|---|---|
| DVP-06 | ThermoSnow | Incorrect threshold | Thermal/colour cycles | 0–25 °C | 30 | 8±2 °C; ≤15 s | ΔE/T curves |
| DVP-12 | Food contact | Migration/NIAS | Overall/specific migration | Cold-fill water use | 3 lots | Applicable regulatory compliance | Signed report |
07 · FAILURE MODES
Failure modes,
causes and controls.
Body brittleness
EffectBreakage/leak
CausePHA thermal window
ControlDSC/TGA, rheology, process DOE
Non-uniform walls
EffectBuckling/drop failure
CauseAsymmetric geometry
ControlBlow-moulding CAE + micro-CT
AeroSkin detachment
EffectLoss of function/loose part
CauseInsufficient seal
ControlPeel, thermal cycling and drop
08 · EVIDENCE POLICY
Traceability
for every parameter.
The absence of electronics removes batteries and circuitry. The active system is still an additive material, so its mass, migration and end-of-life behaviour must be qualified.
This page is the technical register for the R2 configuration. It separates design values, targets, calculations, measurements and certifications. Open fields identify the exact test or document required to close them.