← EXPLODED VIEWP06

COMPONENT TECHNICAL DOSSIER

Snowflake Base

The six-lobe signature must not create instability: the visual form is subordinate to a genuine standing ring.

PRE-INDUSTRIAL R2CONTINUOUS STANDING RING
Technical study of the Snowflake base and standing ring
P06 · REFERENCE CONFIGURATION
20registered technical fields
10engineering disciplines
6basis / calculated / measured
1targets to be demonstrated
13fields requiring evidence

01 · PRINCIPLE & RATIONALE

Intended function
and associated requirement.

PRINCIPLE

The six-lobe signature must not create instability: the visual form is subordinate to a genuine standing ring.

WHY IT IS INCLUDED

The bottle remains steady on a worktop, in a refrigerator and in a case, while its body profile resists rolling when laid on its side.

DETAILED DESCRIPTION

Retains the six-lobe signature while standing on a continuous anti-rocking ring. Six radial ribs converge on the push-up; a continuous 360° ring defines the contact plane and separates visual identity from static performance. Rocking and the limit angle on an inclined plane must be measured on full and empty samples; a rendering does not demonstrate stability.

02 · TECHNOLOGY STACK

Technologies, roles
and approval gates.

T-01

Continuous standing ring

Role
Defines a true 360° contact plane.
Why
Separates stability from the six-lobe visual signature.
Approval gate
Standing-plane, rocking and inclined-plane tests.
T-02

Six radial ribs

Role
Carry load from the body to the push-up.
Why
Distribute top-load and impact without separate feet.
Approval gate
CAE, wall map and base drop.
T-03

Central push-up

Role
Manages pressure, deformation and base cooling.
Why
Avoids an unstable centre and controls forming memory.
Approval gate
Tooling DOE and post-ageing flatness.

03 · ARCHITECTURE

Function, material
and interfaces.

Six radial ribs converge on the push-up; a continuous 360° ring defines the contact plane and separates visual identity from static performance.

MATERIALIntegral to the AQUA-PHA body
CANDIDATE PROCESSFormed in the body mould
INTERFACES
  • Six body ribs
  • central push-up
FUNCTIONAL ARCHITECTURE
  1. 01Continuous standing ring
  2. 02Central push-up
  3. 03Ribs connected to the body
  4. 04Visual signature without separate feet

04 · MASTER PARAMETER REGISTER

Everything to be defined,
measured or certified.

A field without evidence is never filled with an invented number: it remains “To be determined”, together with the method required to close it. This is what makes the technical record verifiable.

DESIGN BASISTARGETCALCULATED / MEASUREDTO BE VALIDATEDCERTIFICATION REQUIRED
01Identification & function3 PARAMETERS
IDParameterSymbolValueUnitToleranceConditionMethodStatus
P06-001Assembly codeIDP06—To be defined23 °C / 50% RH unless notedCAD, CAE or dedicated testDESIGN BASIS
P06-002DesignationNAMESnowflake Base—To be defined23 °C / 50% RH unless notedCAD, CAE or dedicated testDESIGN BASIS
P06-X001Intended useUSETo be determined—To be definedFull use cycleDesign review + user studyTO BE VALIDATED
02Risk & maturity2 PARAMETERS
IDParameterSymbolValueUnitToleranceConditionMethodStatus
P06-003Architecture revisionREVR2—To be defined23 °C / 50% RH unless notedCAD, CAE or dedicated testDESIGN BASIS
P06-004Technology readinessTRL2–3levelTo be defined23 °C / 50% RH unless notedCAD, CAE or dedicated testTO BE VALIDATED
03Food contact2 PARAMETERS
IDParameterSymbolValueUnitToleranceConditionMethodStatus
P06-005Declaration of ComplianceDoCrequireddocumentTo be defined23 °C / 50% RH unless notedCAD, CAE or dedicated testCERTIFICATION REQUIRED
P06-X007Overall and specific migrationMIGTo be determinedmg/kgApplicable limitsSimulant/time/temperatureAccredited methodsTO BE VALIDATED
04Quality control2 PARAMETERS
IDParameterSymbolValueUnitToleranceConditionMethodStatus
P06-006Lot traceabilityLOT100%To be defined23 °C / 50% RH unless notedCAD, CAE or dedicated testTARGET
P06-X006Process capabilityCpkTo be determined—Target to be definedCritical CTQSPC ≥30 samplesTO BE VALIDATED
05Geometry & metrology4 PARAMETERS
IDParameterSymbolValueUnitToleranceConditionMethodStatus
P06-007Number of lobesnlobe6no.To be defined23 °C / 50% RH unless notedCAD, CAE or dedicated testDESIGN BASIS
P06-008Number of radial ribsnrib6no.To be defined23 °C / 50% RH unless notedCAD, CAE or dedicated testDESIGN BASIS
P06-009Contact surfaceRING360°To be defined23 °C / 50% RH unless notedCAD, CAE or dedicated testDESIGN BASIS
P06-X002Nominal massmTo be determinedgTo be defined23 °C / 50% RHBalance 0.001 gTO BE VALIDATED
06Mechanical properties3 PARAMETERS
IDParameterSymbolValueUnitToleranceConditionMethodStatus
P06-010Maximum rockingROCKto be measuredmmTo be defined23 °C / 50% RH unless notedCAD, CAE or dedicated testTO BE VALIDATED
P06-011Inclined-plane stabilityTILTto be measured°To be defined23 °C / 50% RH unless notedCAD, CAE or dedicated testTO BE VALIDATED
P06-X005Drop resistanceHdropTo be determinedmTo be definedDefined orientationsInstrumented drop testTO BE VALIDATED
07Manufacturing process1 PARAMETERS
IDParameterSymbolValueUnitToleranceConditionMethodStatus
P06-012Base wall distributionTBASEfrom CAEmmTo be defined23 °C / 50% RH unless notedCAD, CAE or dedicated testSIMULATION
08Material1 PARAMETERS
IDParameterSymbolValueUnitToleranceConditionMethodStatus
P06-X003Commercial grade and supplierGRADETo be determined—Qualified gradeProduction lotCoA + traceabilityTO BE VALIDATED
09Thermal properties1 PARAMETERS
IDParameterSymbolValueUnitToleranceConditionMethodStatus
P06-X004Service-temperature rangeTserviceTo be determined°CTo be definedUse and transportClimate chamberTO BE VALIDATED
10Recyclability1 PARAMETERS
IDParameterSymbolValueUnitToleranceConditionMethodStatus
P06-X008Territory-specific end-of-life routeEOLTo be determined—Country/area definedComplete assemblyInfrastructure mappingTO BE VALIDATED

05 · INDUSTRIALISATION

From material
to final inspection.

INPUT

Qualified material

Integral to the AQUA-PHA body

FORMING

Process within window

Formed in the body mould

INTEGRATION

Controlled interfaces

Six body ribs · central push-up

RELEASE

CTQ + traceability

Wall distribution, cooling and flatness depend on the body mould. Standing-plane testing and CAE must guide the radii before tooling.

06 · DVP&R

A function is approved
only after passing its test.

TestRequirementRiskMethodConditionSamplesAcceptanceOutput
DVP-02Wall-thickness mapWeak zonesMicro-CT3 lots15Conforms to frozen CAEThickness map
DVP-03Top/side loadCollapseCompression23 °C; empty/full30+30≥250 N / ≥80 NForce-displacement curves
DVP-04Filled-bottle dropBreakage/leakDrop1 m; water 4 °C; base/side/cap600 leaks; 0 loose partsFailure map
DVP-10Base rockingInstabilityStanding-planeFull/empty30Limit to be frozenRocking map

07 · FAILURE MODES

Failure modes,
causes and controls.

R-01

Body brittleness

EffectBreakage/leak

CausePHA thermal window

ControlDSC/TGA, rheology, process DOE

RPN 315DVP-02/04
R-02

Non-uniform walls

EffectBuckling/drop failure

CauseAsymmetric geometry

ControlBlow-moulding CAE + micro-CT

RPN 336DVP-02/03
R-03

AeroSkin detachment

EffectLoss of function/loose part

CauseInsufficient seal

ControlPeel, thermal cycling and drop

RPN 280DVP-04/05

08 · EVIDENCE POLICY

Traceability
for every parameter.

The base is integral to the body and adds no separate material. Lightweighting must not compromise stability, drainage or transport resistance.

This page is the technical register for the R2 configuration. It separates design values, targets, calculations, measurements and certifications. Open fields identify the exact test or document required to close them.

← P05Reversible FlowCrownMAPExploded viewP07 →SoftFold Compaction